Permeameters and Infiltrometers

Guelph Permeameter SoilMoistire
Guelph Permeameter, Complete Kit Case

Products

Lab Permeameter, Five Station
Permeameters
Showing 1 – 8 of 8 results Showing all 8 results Showing the single result No results found
Filters Sort results
Reset Apply
Part Number
Reference Number
Specifications
User Manual
Image
Quantity
Add to cart
More Info
PR16

Lab Permeameter (soil core method), Single Station. ASTM D2434 Compliant Learn More About PR16 Permeameters

Lab Permeameter, Single Station,
Max:
Min: 1
Step: 1

Lab Permeameter (soil core method), Single Station.

ASTM D2434 Compliant

PR16-5

Lab Permeameter, Five Station ASTM D2434 Compliant Learn More About PR16 Permeameters

Lab Permeameter, Five Station
Max:
Min: 1
Step: 1

Lab Permeameter, Five Station

ASTM D2434 Compliant

PR16-SSA

PR16, Slow Soil Attachment, Ksat of 108 to 109 m/s Learn More About PR16 Permeameters

PR16, Slow Soil Attachment, Ksat of 108 to 109 m/s
Max:
Min: 1
Step: 1

PR16, Slow Soil Attachment, Ksat of 108 to 109 m/s

PR16-FSA

PR16, Fast Soil Attachment, Ksat of 103 to 104 m/s Learn More About PR16 Permeameters

PR16, Fast Soil Attachment, Ksat of 103 to 104 m/s
Max:
Min: 1
Step: 1

PR16, Fast Soil Attachment, Ksat of 103 to 104 m/s

2840K1PC + 0237D10L10

Automated Aardvark Permeameter (borehole method, automated), Complete Kit (Including Auger Kit)

Automated Aardvark Permeameter, Complete Kit (Including Auger Kit)
Max:
Min: 1
Step: 1

Automated Aardvark Permeameter (borehole method, automated), Complete Kit (Including Auger Kit)

ASTM D5126 Compliant

Case contents:

2840K1PC

Automated Aardvark Permeameter Kit (No Auger Kit)

Automated Aardvark Permeameter Kit (No Auger Kit)
Max:
Min: 1
Step: 1

Automated Aardvark Permeameter Kit (No Auger Kit)

ASTM D5126 Compliant

Case contents:

2800K1

Guelph Permeameter (borehole method), Complete Kit

Guelph Permeameter, Complete Kit
Max:
Min: 1
Step: 1

Guelph Permeameter (borehole method), Complete Kit.

ASTM D5126 Compliant

2800K4

Guelph Permeameter Kit (No Auger Set, No Carrying Case)

Guelph Permeameter Kit (No Auger Set, No Carrying Case)
Max:
Min: 1
Step: 1

Guelph Permeameter Kit (No Auger Set, No Carrying Case).

ASTM D5126 Compliant

Guelph Tension Infiltrometer Kit, Less Reservoir
Infiltrometers
Showing 1 – 6 of 6 results Showing all 6 results Showing the single result No results found
Filters Sort results
Reset Apply
Part Number
Reference Number
Specifications
User Manual
Image
Quantity
Add to cart
More Info
2805D10K1

Guelph Pressure Infiltrometer (surface method), Complete Kit

Guelph Pressure Infoltrometer, Complete Kit
Max:
Min: 1
Step: 1

Guelph Pressure Infiltrometer (surface method), Complete Kit

2805D10

Guelph Pressure Infiltrometer Kit, Less Reservoir

Gueph Pressure Infoltrometer Kit, Less Reservoir
Max:
Min: 1
Step: 1

Guelph Pressure Infiltrometer Kit, Less Reservoir

2825K1

Guelph Tension Infiltrometer (surface method), Complete Kit

Guelph Tension Infiltrometer, Complete Kit
Max:
Min: 1
Step: 1

Guelph Tension Infiltrometer (surface method), Complete Kit

2825

Guelph Tension Infiltrometer Kit, Less Reservoir

Guelph Tension Infiltrometer Kit, Less Reservoir
Max:
Min: 1
Step: 1

Guelph Tension Infiltrometer Kit, Less Reservoir

2830K3

Double Ring Infiltrometer (surface method), 12″ and 24″ Rings, 3L and 10L Bubblers. ASTM 3885 Compliant

Double Ring Infiltrometer, 12" and 24" Rings, 3L and 10L Bubblers
Max:
Min: 1
Step: 1

Double Ring Infiltrometer (surface method), 12″ and 24″ Rings, 3L and 10L Bubblers.

ASTM 3885 Compliant

2830K2

Double Ring Infiltrometer, 12″ and 24″ Rings, Less Reservoirs. ASTM 3885 Compliant

Double Ring Infiltrometer, 12" and 24" Rings, Less Reservoirs
Max:
Min: 1
Step: 1

Double Ring Infiltrometer, 12″ and 24″ Rings, Less Reservoirs.

ASTM 3885 Compliant

PR16, Flow Cell Cap
Replacement Parts
Showing 1 – 14 of 14 results Showing all 14 results Showing the single result No results found
Filters Sort results
Reset Apply
Part Number
Reference Number
Specifications
User Manual
Image
Quantity
Add to cart
More Info
2805K1

PR15, O RING KIT, FOR 2805D10 PRESSURE INFILTROMETER

PR15, O RING KIT, FOR 2805D10 PRESSURE INFILTROMETER
Max:
Min: 1
Step: 1

PR15, O RING KIT, FOR 2805D10 PRESSURE INFILTROMETER

PR16-RC

PR16, Reciever

PR16, Reciever
Max:
Min: 1
Step: 1

PR16, Reciever

PR16-CP

PR16, Flow Cell Cap

PR16, Flow Cell Cap
Max:
Min: 1
Step: 1

PR16, Flow Cell Cap

2840-1000

PR40, Aardvark Permeameter Module

PR40, Aardvark Permeameter Module
Max:
Min: 1
Step: 1

PR40, Aardvark Permeameter Module

2840-1003-01

PR40, WATER CONTAINER (RESERVOIR)

PR40, WATER CONTAINER (RESERVOIR)
Max:
Min: 1
Step: 1

PR40, WATER CONTAINER (RESERVOIR)

2840-2000

PR40, REGULATOR MODULE ONLY

PR40, REGULATOR MODULE ONLY
Max:
Min: 1
Step: 1

PR40, REGULATOR MODULE ONLY

2844L50

PR40, MEASURING TAPE 50 FEET ASSEMBLY

PR40, MEASURING TAPE 50 FEET ASSEMBLY
Max:
Min: 1
Step: 1

PR40, MEASURING TAPE 50 FEET ASSEMBLY

7201W10PKG

PR40, DIGITAL USB SCALE, 10 KG

PR40, DIGITAL USB SCALE, 10 KG
Max:
Min: 1
Step: 1

PR40, DIGITAL USB SCALE, 10 KG

2800K2

PR80, Guelph Permeameter Extension Kit, 80 CM

PR80, Guelph Permeameter Extension Kit, 80 CM, PR80, 2800K2 plus Auger Extension Kit, 80 CM
Max:
Min: 1
Step: 1

PR80, Guelph Permeameter Extension Kit, 80 CM

2800K5

PR80, 2800K2 plus Auger Extension Kit, 80 CM

PR80, Guelph Permeameter Extension Kit, 80 CM, PR80, 2800K2 plus Auger Extension Kit, 80 CM
Max:
Min: 1
Step: 1

PR80, 2800K2 plus Auger Extension Kit, 80 CM

2800GPSK

PR80, PERMEAMETER SUPPORT KIT

PR80, PERMEAMETER SUPPORT KIT
Max:
Min: 1
Step: 1

PR80, PERMEAMETER SUPPORT KIT

2800K3

PR80, TIP AND COUPLING KIT

PR80, TIP AND COUPLING KIT
Max:
Min: 1
Step: 1

PR80, TIP AND COUPLING KIT

2800K6

PR80, REPLACEMENT RUBBER PARTS, COMPLETE SET

PR80, REPLACEMENT RUBBER PARTS, COMPLETE SET
Max:
Min: 1
Step: 1

PR80, REPLACEMENT RUBBER PARTS, COMPLETE SET

2806F1

PR80, HEAVY DUTY GUELPH STAND

PR80, HEAVY DUTY GUELPH STAND
Max:
Min: 1
Step: 1

PR80, HEAVY DUTY GUELPH STAND

Learn More

Permeameters and Infiltrometers are used to determine how fast water moves through a soil profile. This can be measured and described by several concepts such as infiltration rate, permeability, hydraulic conductivity, etc. Infiltrometer is mostly referred to methods used a one-directional flow.

Environmental Science and Engineering

  • Groundwater Modeling: Determines flow rates and patterns in aquifers for predicting groundwater availability and contamination spread.
  • Contaminant Transport Studies: Helps simulate the movement of pollutants through soil and groundwater.
  • Wetland Hydrology: Supports wetland design and restoration by estimating water movement into and out of saturated soils.

Civil Engineering

  • Geotechnical Engineering:
    • Used in designing foundations, especially in saturated soils.
    • Assesses drainage characteristics for slope stability and embankments.
  • Pavement Design:
    • Evaluates subgrade drainage capacity to avoid water-related pavement failures.
  • Construction Dewatering:
    • Helps estimate the rate of groundwater inflow to excavation sites and design appropriate pumping systems.

Agriculture and Soil Science

  • Irrigation Management:
    • Assists in scheduling irrigation by understanding how quickly water percolates through the root zone.
  • Drainage System Design:
    • Informs layout and sizing of subsurface drains for waterlogged fields.
  • Soil Health Assessment:
    • Indicates soil structure and porosity, reflecting compaction and other management impacts.

Hydrology and Water Resources Engineering

  • Watershed Hydrology:
    • Used in hydrologic models (e.g., SWAT, HEC-HMS) to simulate infiltration and baseflow.
  • Flood Prediction and Management:
    • Influences infiltration rates and runoff generation, affecting peak flow predictions.
  • Aquifer Recharge Studies:
    • Determines potential recharge rates and helps manage artificial recharge systems.

Mining and Petroleum Engineering

  • Mine Dewatering and Safety:
    • Helps design drainage systems to control water in mines, especially underground.
  • Oil and Gas Reservoir Analysis:
    • Analogous parameters are used to model fluid flow in porous reservoir rocks.

Climate Science and Ecology

  • Climate Impact Studies:
    • Models soil moisture dynamics in response to climate change scenarios.
  • Ecohydrology:
    • Links water availability with vegetation patterns and ecosystem functioning.

Urban Planning and Infrastructure

  • Stormwater Management:
    • Determines infiltration rates for green infrastructure (e.g., rain gardens, permeable pavements).
  • Septic System Design:
    • Ensures proper percolation rates for wastewater dispersal fields.