Plant Water Potential Consoles

SoilMoisture is a leading manufacturer of research-grade Plant Water Potential Consoles (also known as Scholander pressure bombs) used in universities and commercial applications around the world. Plant Water Potential Console is the direct method for measuring plant water stress level, which has major applications in plant physiology research and irrigation scheduling in grapes, citrus, pistachios, almonds and other high value crops.

SoilMoisture’s Plant Water Potential Consoles are available in portable and desktop configurations and are favored by users for their larger sampling volume, a large built-in sample preparation board and a floating pointer needle to record the maximum pressure.

Products

Plant Water Potential Console, Portable, 80 Bar Application Range, Plant Water Potential Console, Portable, 40 Bar, Less Air Tank, Plant Water Potential Console, Portable, 40 Bar Application Range, Plant Water Potential Console, Portable, 40 Bar, Less Air Tank
Plant Water Potential Consoles
Showing 1 – 8 of 8 results Showing all 8 results Showing the single result No results found
Filters Sort results
Reset Apply
Part Number
Reference Number
Specifications
User Manual
Image
Quantity
Add to cart
More Info
3115P40G4V22

Plant Water Potential Console, Portable, 40 Bar Application Range

Plant Water Potential Console, Portable, 80 Bar Application Range, Plant Water Potential Console, Portable, 40 Bar, Less Air Tank, Plant Water Potential Console, Portable, 40 Bar Application Range, Plant Water Potential Console, Portable, 40 Bar, Less Air Tank
Max:
Min: 1
Step: 1

Plant Water Potential Console, Portable, 40 Bar Application Range

3115P40G4VNI

Plant Water Potential Console, Portable, 40 Bar, Less Air Tank

Plant Water Potential Console, Portable, 80 Bar Application Range, Plant Water Potential Console, Portable, 40 Bar, Less Air Tank, Plant Water Potential Console, Portable, 40 Bar Application Range, Plant Water Potential Console, Portable, 40 Bar, Less Air Tank
Max:
Min: 1
Step: 1

Plant Water Potential Console, Portable, 40 Bar, Less Air Tank

3115P80G4V22

Plant Water Potential Console, Portable, 80 Bar Application Range

Plant Water Potential Console, Portable, 80 Bar Application Range, Plant Water Potential Console, Portable, 40 Bar, Less Air Tank, Plant Water Potential Console, Portable, 40 Bar Application Range, Plant Water Potential Console, Portable, 40 Bar, Less Air Tank
Max:
Min: 1
Step: 1

Plant Water Potential Console, Portable, 80 Bar Application Range

3115P80G4VNI

Plant Water Potential Console, Portable, 40 Bar, Less Air Tank

Plant Water Potential Console, Portable, 80 Bar Application Range, Plant Water Potential Console, Portable, 40 Bar, Less Air Tank, Plant Water Potential Console, Portable, 40 Bar Application Range, Plant Water Potential Console, Portable, 40 Bar, Less Air Tank
Max:
Min: 1
Step: 1

Plant Water Potential Console, Portable, 40 Bar, Less Air Tank

3005F01H07G4P40

Plant Water Potential Console, Desktop, 40 Bar

Plant Water Potential Console, Desktop, 80 Bar, Plant Water Potential Console, Desktop, 80 Bar, Less Air Tank, Plant Water Potential Console, Desktop, 40 Bar, Plant Water Potential Console, Desktop, 40 Bar, Less Air Tank
Max:
Min: 1
Step: 1

Plant Water Potential Console, Desktop, 40 Bar

3000F01H07G4P40

Plant Water Potential Console, Desktop, 40 Bar, Less Air Tank

Plant Water Potential Console, Desktop, 80 Bar, Plant Water Potential Console, Desktop, 80 Bar, Less Air Tank, Plant Water Potential Console, Desktop, 40 Bar, Plant Water Potential Console, Desktop, 40 Bar, Less Air Tank
Max:
Min: 1
Step: 1

Plant Water Potential Console, Desktop, 40 Bar, Less Air Tank

3005F01H07G4P80

Plant Water Potential Console, Desktop, 80 Bar

Plant Water Potential Console, Desktop, 80 Bar, Plant Water Potential Console, Desktop, 80 Bar, Less Air Tank, Plant Water Potential Console, Desktop, 40 Bar, Plant Water Potential Console, Desktop, 40 Bar, Less Air Tank
Max:
Min: 1
Step: 1

Plant Water Potential Console, Desktop, 80 Bar

3000F01H07G4P80

Plant Water Potential Console, Desktop, 80 Bar, Less Air Tank

Plant Water Potential Console, Desktop, 80 Bar, Plant Water Potential Console, Desktop, 80 Bar, Less Air Tank, Plant Water Potential Console, Desktop, 40 Bar, Plant Water Potential Console, Desktop, 40 Bar, Less Air Tank
Max:
Min: 1
Step: 1

Plant Water Potential Console, Desktop, 80 Bar, Less Air Tank

PT15, AirTank, 22 cu ft
Plant Water Potential Console Replacement Parts
Showing 1 – 52 of 52 results Showing all 52 results Showing the single result No results found
Filters Sort results
Reset Apply
Part Number
Reference Number
Specifications
User Manual
Image
Quantity
Add to cart
More Info
3072V22

PT15, AirTank, 22 cu ft

PT15, AirTank, 22 cu ft
Max:
Min: 1
Step: 1

PT15, AirTank, 22 cu ft

0767P0750L05

PT15/PT30/TK22, Hose, Unit to AirTank, Quick Connect and Regulator

PT15/PT30/TK22, Hose, Unit to AirTank, Quick Connect and Regulator
Max:
Min: 1
Step: 1

PT15/PT30/TK22, Hose, Unit to AirTank, Quick Connect and Regulator

0767P2000L05

PT30-80, Hose, Unit to Nitrogen Tank, Quick Connect and Regulator

PT30-80, Hose, Unit to Nitrogen Tank, Quick Connect and Regulator
Max:
Min: 1
Step: 1

PT30-80, Hose, Unit to Nitrogen Tank, Quick Connect and Regulator

0767P2000G3

TK22, Refill Hose, AirTank to NitrogenTank, CGA 580, 5 ft

TK22, Refill Hose, AirTank to NitrogenTank, CGA 580, 5 ft
Max:
Min: 1
Step: 1

TK22, Refill Hose, AirTank to NitrogenTank, CGA 580, 5 ft

3015G4

PT, Specimen Holder, Standard, petioles and grass leaves

PT, Specimen Holder, Standard, petioles and grass leaves
Max:
Min: 1
Step: 1

PT, Specimen Holder, Standard, petioles and grass leaves

3015G2

PT, Specimen Holder, Broad Grass Leaves (1.15″ limit)

PT, Specimen Holder, Broad Grass Leaves (1.15" limit)
Max:
Min: 1
Step: 1

PT, Specimen Holder, Broad Grass Leaves (1.15″ limit)

0783P0600

PT15, Gauge, Dual Scale, 0-40 bar (0-600 psi)

Max:
Min: 1
Step: 1

PT15, Gauge, Dual Scale, 0-40 bar (0-600 psi)

0783P1500

PT15, Gauge, Dual Scale, 0-800 bar (0-1500 psi)

Max:
Min: 1
Step: 1

PT15, Gauge, Dual Scale, 0-800 bar (0-1500 psi)

3115UGD

PT15, PRODUCT UPGRADE

Max:
Min: 1
Step: 1

PT15, PRODUCT UPGRADE

0780P0600

PT30, Gauge, Dual Scale, 0-40 bar (0-600 psi)

Max:
Min: 1
Step: 1

PT30, Gauge, Dual Scale, 0-40 bar (0-600 psi)

0780P1500

PT30, Gauge, Dual Scale, 0-800 bar (0-1500 psi)

Max:
Min: 1
Step: 1

PT30, Gauge, Dual Scale, 0-800 bar (0-1500 psi)

3000.3005UGD

PT30, PRODUCT UPGRADE

Max:
Min: 1
Step: 1

PT30, PRODUCT UPGRADE

3022

PT30, Volume Reducer, 4″

Max:
Min: 1
Step: 1

PT30, Volume Reducer, 4″

3025K1

PTS, Petiole Insertion Tool

Max:
Min: 1
Step: 1

PTS, Petiole Insertion Tool

M802X149PKG04

PTS/PTS-B, BUNA-N O-RING SEAL, 4 PACK

Max:
Min: 1
Step: 1

PTS/PTS-B, BUNA-N O-RING SEAL, 4 PACK

Z3015K1

PTS/PTS-B, SPECIMEN HOLDER RELIEF VALVE REPAIR KIT

Max:
Min: 1
Step: 1

PTS/PTS-B, SPECIMEN HOLDER RELIEF VALVE REPAIR KIT

3024B12

BAGS, 1 DOZEN

BAGS, 1 DOZEN
Max:
Min: 1
Step: 1

BAGS, 1 DOZEN

3019G4D062PK5

PTS, Grommet, Petiole, 1/16″ Hole, 5 Pack

PTS, Grommet, Petiole, 1/16" Hole, 5 Pack
Max:
Min: 1
Step: 1

PTS, Grommet, Petiole, 1/16″ Hole, 5 Pack

3019G4D093PK5

PTS, Grommet, Petiole, 3/32″ Hole, 5 Pack

PTS, Grommet, Petiole, 3/32" Hole, 5 Pack
Max:
Min: 1
Step: 1

PTS, Grommet, Petiole, 3/32″ Hole, 5 Pack

3019G4D125PK5

PTS, Grommet, Petiole, 1/8″ Hole, 5 Pack

PTS, Grommet, Petiole, 1/8" Hole, 5 Pack
Max:
Min: 1
Step: 1

PTS, Grommet, Petiole, 1/8″ Hole, 5 Pack

3019G4D187PK5

PTS, Grommet, Petiole, 3/16″ Hole, 5 Pack

PTS, Grommet, Petiole, 3/16" Hole, 5 Pack
Max:
Min: 1
Step: 1

PTS, Grommet, Petiole, 3/16″ Hole, 5 Pack

3019G4D250PK5

PTS, Grommet, Petiole, 1/4″ Hole, 5 Pack

PTS, Grommet, Petiole, 1/4" Hole, 5 Pack
Max:
Min: 1
Step: 1

PTS, Grommet, Petiole, 1/4″ Hole, 5 Pack

3019G4D375PK5

PTS, Grommet, Petiole, 3/8″ Hole, 5 Pack

PTS, Grommet, Petiole, 3/8" Hole, 5 Pack
Max:
Min: 1
Step: 1

PTS, Grommet, Petiole, 3/8″ Hole, 5 Pack

3019G4D500PK5

PTS, Grommet, Petiole, 1/2″ Hole, 5 Pack

PTS, Grommet, Petiole, 1/2" Hole, 5 Pack
Max:
Min: 1
Step: 1

PTS, Grommet, Petiole, 1/2″ Hole, 5 Pack

3019G4DBLKPK5

PTS, Grommet, Blank, 5 Pack

PTS, Grommet, Blank, 5 Pack
Max:
Min: 1
Step: 1

PTS, Grommet, Blank, 5 Pack

3019G4UTA01PK5

PTS, Grommet, Leaf, Arc 1/8″ Wide by 1/2″, 5 Pack

PTS, Grommet, Leaf, Arc 1/8" Wide by 1/2", 5 Pack
Max:
Min: 1
Step: 1

PTS, Grommet, Leaf, Arc 1/8″ Wide by 1/2″, 5 Pack

3019G4UTE01PK5

PTS, Grommet, Leaf, Ellips 1/16″ Wide by 1/4″, 5 Pack

PTS, Grommet, Leaf, Ellips 1/16" Wide by 1/4", 5 Pack
Max:
Min: 1
Step: 1

PTS, Grommet, Leaf, Ellips 1/16″ Wide by 1/4″, 5 Pack

3019G4UTE02PK5

PTS, Grommet, Leaf, Ellips 1/8″ Wide by 1/2″, 5 Pack

PTS, Grommet, Leaf, Ellips 1/8" Wide by 1/2", 5 Pack
Max:
Min: 1
Step: 1

PTS, Grommet, Leaf, Ellips 1/8″ Wide by 1/2″, 5 Pack

3019G4UTS01PK5

PTS, Grommet, Leaf, Slot .050″ Wide by 1/2″, 5 Pack

PTS, Grommet, Leaf, Slot .050" Wide by 1/2", 5 Pack
Max:
Min: 1
Step: 1

PTS, Grommet, Leaf, Slot .050″ Wide by 1/2″, 5 Pack

3018G4D062PK5

PTS, Sealing Sleeve, 1/2″ O.D., 1/16″ Dia.Hole, 5 Pack

Max:
Min: 1
Step: 1

PTS, Sealing Sleeve, 1/2″ O.D., 1/16″ Dia.Hole, 5 Pack

3018G4D125PK5

PTS, Sealing Sleeve, 1/2″ O.D., 1/8″ Dia. Hole, 5 Pack

Max:
Min: 1
Step: 1

PTS, Sealing Sleeve, 1/2″ O.D., 1/8″ Dia. Hole, 5 Pack

3018G4D187PK5

PTS, Sealing Sleeve, 1/2″ O.D., 3/16” Dia. Hole, 5 Pack

Max:
Min: 1
Step: 1

PTS, Sealing Sleeve, 1/2″ O.D., 3/16” Dia. Hole, 5 Pack

3018G4D250PK5

PTS, Sealing Sleeve, 1/2″ O.D., 1/4″ Dia. Hole, 5 Pack

Max:
Min: 1
Step: 1

PTS, Sealing Sleeve, 1/2″ O.D., 1/4″ Dia. Hole, 5 Pack

3018G4DBLKPK5

PTS, Sealing Sleeve, 1/2” O.D., Blank, 5 Pack

Max:
Min: 1
Step: 1

PTS, Sealing Sleeve, 1/2” O.D., Blank, 5 Pack

3020G4D141PK5

PTS, Support Washer, PTS,, 9/64″ Dia. Hole, 5 Pack

PTS, Support Washer, Blank, 5 Pack / PTS, Support Washer, PTS,, 9/64" Dia. Hole, 5 Pack
Max:
Min: 1
Step: 1

PTS, Support Washer, PTS,, 9/64″ Dia. Hole, 5 Pack

3020G4D250PK5

PTS, Support Washer, PTS,, 1/4″ Dia. Hole, 5 Pack

PTS, Support Washer, PTS,, 1/4" Dia. Hole, 5 Pack
Max:
Min: 1
Step: 1

PTS, Support Washer, PTS,, 1/4″ Dia. Hole, 5 Pack

3020G4D375PK5

PTS, Support Washer, PTS,, 3/8″ Dia. Hole, 5 Pack

PTS, Support Washer, PTS,, 3/8" Dia. Hole, 5 Pack
Max:
Min: 1
Step: 1

PTS, Support Washer, PTS,, 3/8″ Dia. Hole, 5 Pack

3020G4D500PK5

PTS, Support Washer, PTS,, 1/2″ Dia. Hole, 5 Pack

PTS, Support Washer, PTS,, 1/2" Dia. Hole, 5 Pack
Max:
Min: 1
Step: 1

PTS, Support Washer, PTS,, 1/2″ Dia. Hole, 5 Pack

3020G4UTE01PK5

PTS, Support Washer, Slot, 1/16″ Wide X 1/2″ , 5 Pack

PTS, Support Washer, Slot, 1/16" Wide X 1/2" , 5 Pack
Max:
Min: 1
Step: 1

PTS, Support Washer, Slot, 1/16″ Wide X 1/2″ , 5 Pack

3020G4UTE02PK5

PTS, Support Washer, Slot, 1/8″ Wide X 1/2″ , 5 Pack

PTS, Support Washer, Slot, 1/8" Wide X 1/2" , 5 Pack
Max:
Min: 1
Step: 1

PTS, Support Washer, Slot, 1/8″ Wide X 1/2″ , 5 Pack

3020G4BLKPK5

PTS, Support Washer, Blank, 5 Pack

PTS, Support Washer, Blank, 5 Pack / PTS, Support Washer, PTS,, 9/64" Dia. Hole, 5 Pack
Max:
Min: 1
Step: 1

PTS, Support Washer, Blank, 5 Pack

3020G4K1

PTS, Complete Support Washer Kit

PTS, Complete Support Washer Kit
Max:
Min: 1
Step: 1

PTS, Complete Support Washer Kit

3018G4K1

PTS, Sealing Sleeve, Washers, Full Set

PTS, Sealing Sleeve, Washers, Full Set
Max:
Min: 1
Step: 1

PTS, Sealing Sleeve, Washers, Full Set

3019G4K3

PTS, Grommet + Sleeve + Washer, Complete Kit

PTS, Grommet + Sleeve + Washer, Complete Kit
Max:
Min: 1
Step: 1

PTS, Grommet + Sleeve + Washer, Complete Kit

3017G2W050PK5

PTS-B, Grommet, Leaf, 1.15″ X.050″, 5 Pack

Max:
Min: 1
Step: 1

PTS-B, Grommet, Leaf, 1.15″ X.050″, 5 Pack

3017G2W090PK5

PTS-B, Grommet, Leaf, 1.15″ X .094″, 5 Pack

Max:
Min: 1
Step: 1

PTS-B, Grommet, Leaf, 1.15″ X .094″, 5 Pack

3017G2WBLKPK5

PTS-B, Grommet, Leaf, Blank, 5 Pack

Max:
Min: 1
Step: 1

PTS-B, Grommet, Leaf, Blank, 5 Pack

3017G2WRZRPK5

PTS-B, Grommet, Leaf, Razor Cut, 5 Pack

Max:
Min: 1
Step: 1

PTS-B, Grommet, Leaf, Razor Cut, 5 Pack

3021G2W062PK5

PTS-B, Washer, Slot, 1/16″ , 5 PACK

Max:
Min: 1
Step: 1

PTS-B, Washer, Slot, 1/16″ , 5 PACK

3021G2WBLKPK5

PTS-B, Washer, Blank, 5 PACK

Max:
Min: 1
Step: 1

PTS-B, Washer, Blank, 5 PACK

3017G2K1

PTS-B,Grommet, Complete Kit

PTS-B,Grommet, Complete Kit
Max:
Min: 1
Step: 1

PTS-B,Grommet, Complete Kit

3115K1

PT15, PT30, SAPS II ACCESSORY KIT

PT15, PT30, SAPS II ACCESSORY KIT
Max:
Min: 1
Step: 1

PT15, PT30, SAPS II ACCESSORY KIT

Learn more about the Soil Moisture Retention Curve

Measuring plant water tension (often expressed as leaf water potential or stem water potential) is essential for understanding how plants manage water stress. This measurement helps researchers and growers assess the hydration status of plants under various conditions. Here’s how plant water tension measurements are applied across agriculture research, wine grape production, horticulture, and plant physiology research and education:

Agriculture Research

  • Irrigation Management Studies: Determine optimal irrigation schedules by identifying critical water stress thresholds for various crops.
  • Drought Resistance Breeding: Screen and compare crop varieties for their ability to maintain turgor and function under low water availability.
  • Crop Yield Optimization: Correlate water tension levels with biomass and yield to develop water-efficient farming strategies.
  • Soil-Plant Interaction Studies: Evaluate how soil texture, moisture retention, and amendments affect plant water uptake and stress.

Wine Grape Production (Viticulture)

  • Precision Irrigation (Deficit Irrigation): Apply just enough water to maintain desired stress levels that enhance grape quality (e.g., sugar, anthocyanin, and tannin concentrations).
  • Quality Control: Use water potential thresholds to control vegetative growth and improve berry composition, aroma, and skin-to-juice ratios.
  • Ripening Management: Adjust irrigation during veraison (onset of ripening) based on water tension readings to influence flavor and acidity.
  • Clone and Rootstock Evaluation: Compare different grapevine cultivars and rootstocks for their water-use efficiency and drought tolerance.

Horticulture

  • Greenhouse and Nursery Watering Practices: Avoid over- or under-watering in high-value ornamental plants, container crops, or young seedlings.
  • Transplant Shock Monitoring: Assess how quickly transplants re-establish their water uptake ability.
  • Drought Stress Hardening: Apply controlled water stress to improve resilience in ornamentals or turfgrass.
  • Pest and Disease Management: Water-stressed plants are more susceptible to diseases; early detection helps in preventative treatments.

Plant Physiology Research & Education

  • Water Relations Studies: Demonstrate concepts like turgor pressure, osmotic potential, and xylem transport.
  • Stomatal Regulation Research: Correlate water potential with stomatal conductance, transpiration, and photosynthesis.
  • Hydraulic Conductivity Studies: Investigate how water tension affects root, stem, and leaf water transport.
  • Educational Demonstrations: Use pressure chambers or psychrometers in teaching labs to show how plants respond to water stress in real time.